{"product_id":"atlas-scientific-conductivity-probe","title":"Atlas Scientific Leitfähigkeitsfühler K 1.0","description":"\u003cdiv class=\"product-block-list__item product-block-list__item--description details_product\"\u003e\u003cdiv class=\"card\"\u003e\u003cdiv class=\"card__header\"\u003e\r\n\u003ch2 class=\"card__title heading h3\"\u003eBeschreibung\u003c\/h2\u003e\r\n\u003c\/div\u003e\u003cdiv class=\"card__section expandable-content desc-view-more\" id=\"main-description\"\u003e\u003cdiv class=\"rte text--pull\"\u003e\u003cul\u003e\n\u003cli\u003eAtlas Scientific Leitfähigkeitsfühler K 1.0\u003c\/li\u003e\n\u003cli\u003eGewährleistet präzise Leitfähigkeitsmessungen\u003c\/li\u003e\n\u003cli\u003eFunktioniert unter verschiedenen Bedingungen\u003c\/li\u003e\n\u003cli\u003eNutzt eine robuste, langlebige Konstruktion\u003c\/li\u003e\n\u003cli\u003eBietet minimale Neukalibrierungsanforderungen\u003c\/li\u003e\n\u003cli\u003eUnterstützt die Integration in verschiedene Systeme\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDer \u003cstrong\u003eAtlas Scientific Leitfähigkeitsfühler K 1.0\u003c\/strong\u003e ist darauf ausgelegt, präzise und stabile Leitfähigkeitsmessungen über ein breites Spektrum von Bedingungen hinweg zu liefern. Im Gegensatz zu vielen minderwertigen Sonden, die unter dem 'Fringe-Effekt' leiden, gewährleistet diese Sonde Genauigkeit, indem sie konsistente Messwerte beibehält, selbst in der Nähe anderer Objekte. Dies macht sie zur idealen Wahl für Anwendungen, die eine zuverlässige Datenerfassung erfordern.\u003c\/p\u003e\n\u003cp\u003eDer Fühler ist für Langlebigkeit und den langfristigen Einsatz konzipiert und enthält keinen Elektrolyten, der mit der Zeit erschöpft werden könnte, sodass eine Kalibrierung nur während der Installation erforderlich ist. Seine robuste Konstruktion ermöglicht es ihm, unter verschiedenen Umweltbedingungen effektiv zu funktionieren, einschließlich eines breiten Temperaturbereichs und erheblicher Tiefen.\u003c\/p\u003e\n\u003cp\u003eDie Langlebigkeit des Fühlers wird durch seine verlängerte Lebensdauer und minimale Neukalibrierungsanforderungen weiter verbessert, was ihn zu einer kosteneffizienten Lösung für die kontinuierliche Überwachung macht. Sein Design umfasst einen männlichen SMA-Stecker, mit einem optionalen männlichen BNC-Stecker, und ein ein-Meter-Kabel, das die Kompatibilität mit einer Vielzahl von Systemen und die einfache Integration in bestehende Setups gewährleistet.\u003c\/p\u003e\n\u003c\/div\u003e\u003cbutton class= \"expandable-content__toggle\" aria-expanded=\"false\" aria-controls=\"main-description\"\u003e\u003cspan class=\"expandable-content__toggle-icon\"\u003e\u003c\/span\u003e\u003cspan class=\"expandable-content__toggle-text\" data-view-more=\"Mehr sehen\" data-view-less=\"Weniger sehen\"\u003eMehr sehen\u003c\/span\u003e\u003c\/button\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"card details_product\"\u003e\u003cbutton class=\"card__collapsible-button\" data-action=\"toggle-collapsible\" aria-expanded=\"false\" aria-controls=\"unique-tab-2\"\u003e\r\n\u003cspan class=\"card__title heading h3\"\u003eWas ist inbegriffen\u003c\/span\u003e\r\n\u003cspan\u003e\r\n\u003csvg focusable=\"false\" class=\"icon icon--arrow-bottom\" viewBox=\"0 0 12 8\" role=\"presentation\"\u003e\r\n\u003cpath stroke=\"currentColor\" stroke-width=\"2\" d=\"M10 2L6 6 2 2\" fill=\"none\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\r\n\u003c\/svg\u003e\r\n\u003c\/span\u003e\r\n\u003c\/button\u003e\r\n\u003cdiv id=\"unique-tab-2\" class=\"card__collapsible\"\u003e\r\n\u003cdiv class=\"card__collapsible-content\"\u003e\r\n\u003cdiv class=\"rte text--pull\"\u003e\r\n\u003cul\u003e\n\u003cli\u003e1x Atlas Scientific Leitfähigkeitsfühler K 1.0\u003c\/li\u003e\n\u003c\/ul\u003e\n\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"card details_product\"\u003e\u003cbutton class=\"card__collapsible-button\" data-action=\"toggle-collapsible\" aria-expanded=\"false\" aria-controls=\"unique-tab-3\"\u003e\r\n\u003cspan class=\"card__title heading h3\"\u003eMaße\u003c\/span\u003e\r\n\u003cspan\u003e\r\n\u003csvg focusable=\"false\" class=\"icon icon--arrow-bottom\" viewBox=\"0 0 12 8\" role=\"presentation\"\u003e\r\n\u003cpath stroke=\"currentColor\" stroke-width=\"2\" d=\"M10 2L6 6 2 2\" fill=\"none\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\r\n\u003c\/svg\u003e\r\n\u003c\/span\u003e\r\n\u003c\/button\u003e\r\n\u003cdiv id=\"unique-tab-3\" class=\"card__collapsible\"\u003e\r\n\u003cdiv class=\"card__collapsible-content\"\u003e\r\n\u003cdiv class=\"rte text--pull\"\u003e\r\n\u003cp style=\"text-align: center;\"\u003e\u003cimg alt=\"Conductivity Probe K 1.0 Dimensions - Dimensions\" src=\"https:\/\/cdn.robotshop.com\/media\/a\/atl\/rb-atl-41\/img\/atlas_scientific_conductivity_probe_k_1_0_dims.webp\" style=\"width: 600px;\" \/ loading=\"lazy\"\u003e\u003c\/p\u003e\n\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"card details_product\"\u003e\u003cbutton class=\"card__collapsible-button\" data-action=\"toggle-collapsible\" aria-expanded=\"false\" aria-controls=\"unique-tab-4\"\u003e\r\n\u003cspan class=\"card__title heading h3\"\u003eLinks\u003c\/span\u003e\r\n\u003cspan\u003e\r\n\u003csvg focusable=\"false\" class=\"icon icon--arrow-bottom\" viewBox=\"0 0 12 8\" role=\"presentation\"\u003e\r\n\u003cpath stroke=\"currentColor\" stroke-width=\"2\" d=\"M10 2L6 6 2 2\" fill=\"none\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\r\n\u003c\/svg\u003e\r\n\u003c\/span\u003e\r\n\u003c\/button\u003e\r\n\u003cdiv id=\"unique-tab-4\" class=\"card__collapsible\"\u003e\r\n\u003cdiv class=\"card__collapsible-content\"\u003e\r\n\u003cdiv class=\"rte text--pull\"\u003e\r\n\n\u003cp\u003e\u003cstrong\u003ePDF-Dateien\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=https:\/\/cdn.robotshop.com\/media\/A\/Atl\/RB-Atl-41\/pdf\/atlas_scientific_conductivity_probe_k_1_0_datasheet.pdf target=\"_blank\"\u003eAtlas Scientific Leitfähigkeitsfühler K 1.0 - Datenblatt\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=https:\/\/cdn.robotshop.com\/media\/A\/Atl\/RB-Atl-41\/pdf\/atlas_scientific_conductivity_probe_k_1_0_legacy_datasheet.pdf target=\"_blank\"\u003eAtlas Scientific Leitfähigkeitsfühler K 1.0 - Legacy-Datenblatt\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eZIP-Datei\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=https:\/\/cdn.robotshop.com\/media\/A\/Atl\/RB-Atl-41\/zip\/atlas_scientific_conductivity_probe_k_1_0_3d_model.zip target=\"_blank\"\u003eAtlas Scientific Leitfähigkeitsfühler K 1.0 - 3D-Modell\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"card details_product\"\u003e\u003cbutton class=\"card__collapsible-button\" data-action=\"toggle-collapsible\" aria-expanded=\"false\" aria-controls=\"unique-tab-7\"\u003e\r\n\u003cspan class=\"card__title heading h3\"\u003eSpezifikationen\u003c\/span\u003e\r\n\u003cspan\u003e\r\n\u003csvg focusable=\"false\" class=\"icon icon--arrow-bottom\" viewBox=\"0 0 12 8\" role=\"presentation\"\u003e\r\n\u003cpath stroke=\"currentColor\" stroke-width=\"2\" d=\"M10 2L6 6 2 2\" fill=\"none\" stroke-linecap=\"square\"\u003e\u003c\/path\u003e\r\n\u003c\/svg\u003e\r\n\u003c\/span\u003e\r\n\u003c\/button\u003e\r\n\u003cdiv id=\"unique-tab-7\" class=\"card__collapsible\"\u003e\r\n\u003cdiv class=\"card__collapsible-content\"\u003e\r\n\u003cdiv class=\"rte text--pull\"\u003e\r\n\u003cul\u003e\n\u003cli\u003eLeitfähigkeitsbereich: 5 − 200.000 μS\/cm\u003c\/li\u003e\n\u003cli\u003eGenauigkeit: ±2%\u003c\/li\u003e\n\u003cli\u003eAnsprechzeit: 90% in 1 Sekunde\u003c\/li\u003e\n\u003cli\u003eTemperaturbereich: 1 − 110 °C\u003c\/li\u003e\n\u003cli\u003eMaximaler Druck: 3.447 kPa (500 psi)\u003c\/li\u003e\n\u003cli\u003eMaximale Tiefe: 352 m (1.157 Fuß)\u003c\/li\u003e\n\u003cli\u003eStecker: Männlich SMA \/ Männlich BNC (optional)\u003c\/li\u003e\n\u003cli\u003eKabellänge: 1 m\u003c\/li\u003e\n\u003cli\u003eInterner Temperatursensor: Nein\u003c\/li\u003e\n\u003cli\u003eZeit vor Neukalibrierung: ungefähr 10 Jahre\u003c\/li\u003e\n\u003cli\u003eLebenserwartung: ungefähr 10 Jahre\u003c\/li\u003e\n\u003c\/ul\u003e\n\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\r\n\u003c\/div\u003e\u003c\/div\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":49796598432080,"sku":"RB-Atl-41","price":153.98,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0573\/1486\/9416\/files\/atlas-scientific-conductivity-probe-k-10-img1.webp?v=1742535896","url":"https:\/\/eu.robotshop.com\/de\/products\/atlas-scientific-leitfahigkeitsfuhler","provider":"RobotShop Europe","version":"1.0","type":"link"}